The value is 2.00 cubic inches, so multiplying that value by 2 gives you the 4.00 cubic inches for the installed device.ģ) C, straps. To find that value, go to Table 314.16(B) and find the value for 14 AWG conductors. For example, if a switch on a yoke is connected with 14 AWG conductors, the switch volume allowance would be 4 cubic inches. 314.16(B)(4) requires a double volume allowance for device or equipment fill. Use of messenger-supported wiring if specifically permitted by other articles of the NEC.Ģ) B, double. In hazardous locations, 396.10(C) allows the (Fill-in-the-blank questions are looking for the exact word(s) used in the NEC.)ġ) Messenger-supported wiring shall not be used in _ or where subject to physical damage.Ģ) For each yoke or strap containing one or more devices or equipment, a _ volume allowance in accordance with Table 314.16(B) shall be made for each yoke or strap based on the largest conductor connected to a device(s) or equipment supported by that yoke or strap.ģ) Type MC cable shall be supported and secured by staples, cable ties, _, hangers, or similar fittings or other approved means designed and installed so as not to damage the cable.Ĥ) Receptacles mounted to and supported by a cover shall be held rigidly against the cover by more than one screw or shall be a(n) _ or box cover listed and identified for securing by a single screw.ĥ) _, together with their mounting and conductor attachments, where used as supports for wires, single-conductor cables, or busbars, shall be capable of safely withstanding the maximum magnetic forces that would prevail if two or more conductors of a circuit were subjected to short-circuit current.Ħ) Open conductors shall be supported on _ or porcelain knobs, racks, brackets, or strain insulators.ħ) The _ shall be of adequate strength or be supported by braces or guys to withstand safely the strain imposed by the service-drop or overhead service conductors.Ĩ) At what distance must supports for the conductors inside an MC Cable be installed in a vertical installation if the ungrounded conductors are 250 kcmil copper?ĩ) Can an electrical equipment enclosure above deck level on a pier in a marina be supported solely by the conduit(s)?ġ0) Is all electrical equipment prohibited from being supported by trees or other vegetation?ģ96.12 prohibits the use of messenger-supported wiring in hoistways.

#2014 nec codebook code

To play this game, you need a sharp eye, a quick mind and a 2014 National Electrical Code book.










2014 nec codebook